The BD-3E multi-function transducer from Acrel has temperature coefficient of 200ppm/°C, reaction time of 400ms, and accuracy class of 0.5%. It can be mounted using a 35mm DIN rail or screw fixation and runs on an auxiliary power supply of 85V–265V AC, 100V–350V DC, or 24V–48V DC (for some variants).

bd 3e
bd 3e
multi function transducer
4 20ma current transformer
4 20ma transducer
Products

Specification of BD-3E AC Multi-function Transducer

Differential Technical Specification
General Technical Specification
Series Overview
Model Name
MeasurementInputOutputPower Supply
BA-AI

1-phase

AC Current

0~1A AC/0~5A AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

1-phase 2-wire
BA-3I3

3-phase

AC Current

0~1A AC/0~5A AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 3-wire
BA-AV

1-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

1-phase 2-wire
BA-3V3

3-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 3-wire
BA-4V3

3-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 4-wire
BD-DI

1-phase

DC Current

4~20mA DC/0~20mA DC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

1-phase 2-wire
BD-DV

1-phase

DC Voltage

0~75mV DC/0~10V DC

/0~300V DC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

1-phase 2-wire
BD-3P

3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4P

3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-3Q

3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4Q

3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-3/P/Q/I

3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4/P/Q/I

3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-PF

3-phase

Power-Factor

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-F

3-phase

Frequency

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-3E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire


Item
Description
Auxiliary Power Supply85V~265V AC or 100V~350V DC or 24V/48V DC (for certain models)
Accuracy Class
0.5%
Load Resistance (Output)
Current Output: ≤600Ω; Voltage Output: ≤1000Ω
Response Time
≤400ms
Temperature
Operation Temp.: -10℃~+55℃; Storage Temp.: -25℃~+70℃
Temperature Coefiicient
≤200ppm/℃
Humidity≤90%
Altitude
≤2500m
Installation
35mm DIN Rail or Screw fixed
StandardCE


Model Name
MeasurementInputOutputWiring
BA-AI

1-phase

AC Current

0~1A AC/0~5A AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

1-phase 2-wire
BA-3I3

3-phase

AC Current

0~1A AC/0~5A AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 3-wire
BA-AV

1-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

1-phase 2-wire
BA-3V3

3-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 3-wire
BA-4V3

3-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 4-wire
BD-DI

1-phase

DC Current

4~20mA DC/0~20mA DC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

1-phase 2-wire
BD-DV

1-phase

DC Voltage

0~75mV DC/0~10V DC

/0~300V DC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

1-phase 2-wire
BD-3P

3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4P

3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-3Q

3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4Q

3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-3/P/Q/I

3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4/P/Q/I

3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-PF

3-phase

Power-Factor

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-F

3-phase

Frequency

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire
BD-3E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 3-wire
BD-4E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

3-phase 4-wire


Diagram of BD-3E AC Multi-function Transducer

Diagram of BD-3E AC Multi-function Transducer
Series Overview
Diagram of BD-3E AC Multi-function Transducer
Dimension
Diagram of BD-3E AC Multi-function Transducer
Dimension
Diagram of BD-3E AC Multi-function Transducer
Dimension
Innovation, Efficiency, Unity, Integrity.
Acrel, your reliable energy meter partner. Don't hesitate to contact us!
Contact Us
Related BD Series Electrical Transducer
+8618795636361 michelle.zhou@email.acrel.cn
No. 9 Xincheng Road, Chengjiang Street, Jiangyin City, Jiangsu Province, China.