Acrel BA50L-AI/I AC Leakage Current Transformer

Acrel's BA50L-AI/I Leakage Current Transformer is also known as an Earth Leakage Current Transformer, it boasts an accuracy class of 0.5%, with a response time of under 350ms. With a temperature range of -10℃~+55℃ and altitude of ≤2500m, it can be installed on a 35mm DIN rail or screw-fixed. CE/TüV certified, it's the perfect solution for all your leakage current sensing needs.

leakage current transformer
leakage current transformer
earth leakage current transformer
earth leakage transformer
Products

Specification of BA50L-AI/I AC Leakage Current Transformer

Differential Technical Specification
General Technical Specification
Model Name
InputOutputPerforation Hole Size(mm)
AC  CurrentDC CurrentDC Voltage
BA05-AI/I
0~(0.5~10)A4~20mA/0~20mA/φ5
BA05-AI/V
0~(0.5~10)A/1~5V/0~5V
BA10-AI/I
0~(8~50)A4~20mA/0~20mA/φ10
BA10-AI/V
0~(8~50)A/1~5V/0~5V
BA20-AI/I
0~(40~200)A4~20mA/0~20mA/φ20
BA20-AI/V
0~(40~200)A/1~5V/0~5V
BA50-AI/I
0~(60~600)A4~20mA/0~20mA/
φ50

BA50-AI/V
0~(60~600)A/1~5V/0~5V
BA50L-AI/I
0~(0.1~1)A4~20mA/0~20mA/
BA50L-AI/V
0~(0.1~1)A/1~5V/0~5V


Item
Description
Auxiliary Power SupplyDC 12V (range of 10~15V) or DC 24V (range of 18~30V)
Accuracy Class
0.5%
Load Resistance (Output)
Current Output: ≤500Ω; Voltage Output: ≤1000Ω
Response Time
≤350ms
Temperature
Operation Temp.: -10℃~+55℃; Storage Temp.: -40℃~+80℃
Temperature Coefiicient
≤200ppm/℃
Humidity≤90%
Altitude
≤2500m
Installation
35mm DIN Rail or Screw fixed
StandardCE/TüV


Diagram of BA50L-AI/I AC Leakage Current Transformer

Diagram of BA50L-AI/I AC Leakage Current Transformer
Series Overview
Diagram of BA50L-AI/I AC Leakage Current Transformer
Dimension
Diagram of BA50L-AI/I AC Leakage Current Transformer
Dimension
Diagram of BA50L-AI/I AC Leakage Current Transformer
Wiring Illustration
Diagram of BA50L-AI/I AC Leakage Current Transformer
Wiring Illustration
Diagram of BA50L-AI/I AC Leakage Current Transformer
Wiring Illustration
Diagram of BA50L-AI/I AC Leakage Current Transformer
Installation Instruction
Diagram of BA50L-AI/I AC Leakage Current Transformer
Installation Instruction
Diagram of BA50L-AI/I AC Leakage Current Transformer
Work Site Application
Innovation, Efficiency, Unity, Integrity.
Acrel, your reliable energy meter partner. Don't hesitate to contact us!
Contact Us