With models including the BA10-AI/I and BA10-AI/V, Acrel's AC 0-50A Current Transducer has an accuracy class of 0.50%, response time of ≤350ms, and can be installed on either a 35mm DIN rail or using screws. Plus, it has been certified by both CE and TüV. Perfect for those in need of a 10A or 5Amp current sensor.

50 amp current sensor
50 amp current sensor
20 amp current sensor
30 amp current sensor
basic electronics sensors
Products

Specification of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer

Series Overview
Dimension
Differential Technical Specification
General Technical Specification
Model Name
InputOutputPerforation Hole Size(mm)
AC CurrentDC CurrentDC Voltage
BA05-AI/I
0~(0.5~10)A4~20mA/0~20mA/φ5
BA05-AI/V
0~(0.5~10)A/1~5V/0~5V
BA10-AI/I
0~(8~50)A4~20mA/0~20mA/φ10
BA10-AI/V
0~(8~50)A/1~5V/0~5V
BA20-AI/I
0~(40~200)A4~20mA/0~20mA/φ20
BA20-AI/V
0~(40~200)A/1~5V/0~5V
BA50-AI/I
0~(60~600)A4~20mA/0~20mA/
φ50

BA50-AI/V
0~(60~600)A/1~5V/0~5V
BA50L-AI/I
0~(0.1~1)A4~20mA/0~20mA/
BA50L-AI/V
0~(0.1~1)A/1~5V/0~5V


Model NameOutline Size (mm)
WHΦMNL
BA05-AI/I&BA05-AI/V3569562.57622.5
BA10-AI/I&BA10-AI/V35749.562.57622.5
BA20-AI/I&BA20-AI/V3560219310224
BA50-AI/I&BA50-AI/V35845012513524
BA50L-AI/I&BA50L-AI/V35845012513524
Model Name
InputOutputPerforation Hole Size(mm)
AC  CurrentDC CurrentDC Voltage
BA05-AI/I
0~(0.5~10)A4~20mA/0~20mA/φ5
BA05-AI/V
0~(0.5~10)A/1~5V/0~5V
BA10-AI/I
0~(8~50)A4~20mA/0~20mA/φ10
BA10-AI/V
0~(8~50)A/1~5V/0~5V
BA20-AI/I
0~(40~200)A4~20mA/0~20mA/φ20
BA20-AI/V
0~(40~200)A/1~5V/0~5V
BA50-AI/I
0~(60~600)A4~20mA/0~20mA/
φ50

BA50-AI/V
0~(60~600)A/1~5V/0~5V
BA50L-AI/I
0~(0.1~1)A4~20mA/0~20mA/
BA50L-AI/V
0~(0.1~1)A/1~5V/0~5V


ItemDescription
Auxiliary Power SupplyDC 12V (range of 10~15V) or DC 24V (range of 18~30V)
Accuracy Class0.50%
Load Resistance (Output)Current Output: ≤500Ω; Voltage Output: ≤1000Ω
Response Time≤350ms
TemperatureOperation Temp.: -10℃~+55℃; Storage Temp.: -40℃~+80℃
Temperature Coefiicient≤200ppm/℃
Humidity≤90%
Altitude≤2500m
Installation35mm DIN Rail or Screw fixed
StandardCE/TüV


Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer

Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Series Overview
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Dimension
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Dimension
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Wiring Illustration
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Wiring Illustration
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Wiring Illustration
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Installation Instruction
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer
Installation Instruction
Diagram of BA10-AI/I BA10-AI/V AC 0-50A Current Transducer