E-mail

Acrel AKH-0.66/P Protection Current Transformer

AKH-0.66/P protection current transformer is mainly suitable for the relay protection circuit with multiple busbars passing through. This product is developed for the detection of short circuit or overload current in the protection system. It has different accuracy levels and accuracy limit coefficients, and can be expanded to different perforation sizes. It is used in low-voltage power distribution protection The system is widely used in line protection of power plants and industrial and mining enterprises.

protection current transformer
protection current transformer
differential current transformer
differential protection current transformer
Products

Specifications of AKH-0.66/P Protection Current Transformer

Parameter 1
Parameter 2
Parameter 3
SpecificationRated current ratio (A)Precision degree and corresponding rated load
(VA/ Ω)
Straight-through tumsBus spec(mm)/
number
Installation
5P55P105P15
P-60Ⅲ200-250/5( 1)5//160×10/1-3E
300-500/5( 1)52.5/1
600- 1500/5( 1)1052.51
P-80Ⅲ500-600/5( 1)52.5/180×10/1-3
700- 1250/5( 1)105/1
1500/5( 1)1052.51
2000-3000/5( 1)15102.51
P- 100Ⅲ600/5( 1)52.5/1100×10/1-3
700- 1250/5( 1)105/1
1500/5( 1)1052.51
2000-3000/5( 1)15102.51
P- 130Ⅲ1000/5( 1)15102.51130×10/1-3 125×10/1-3
1200- 1250/5( 1)151051
1500-2000/5( 1)201051
2500-3000/5( 1)301551
4000-5000/5( 1)30152.51


SpecificationRated current ratio (A)Precision degree and
corresponding rated load
(VA/ Ω)
Straight-through tumsBus spec(mm)/
number
Installation
5P55P105P155P20
P-60×50II100/5( 1)2.5///160×10/1-3D
150/5( 1)2.51.5//1
200/5( 1)51.5//1
300/5( 1)52.5//1
400/5( 1)102.5//1
500-800/5( 1)1052.5/1
1000-2000/5( 1)151052.51
P-80×50II200-300/5( 1)52.5//180×10/1-3
400-600/5( 1)1052.5/1
1000/5( 1)15105/
800-2000/5( 1)151052.51
2500/5( 1)20151051
P- 100×50II600-800/5( 1)1052.5/1100×10/1-3
1000- 1500/5( 1)151052.51
2000-4000/5( 1)20151051
P- 130×50II600-800/5( 1)1052.5/1120×10/1-3
125×10/1-3
130×10/1-3
1000- 1250/5( 1)151052.51
1500/5( 1)201552.51
2000-2500/5( 1)20151051
3000-5000/5( 1)30151051


SpecificationRated current ratio (A)Precision degree and
corresponding rated load
(VA/ Ω)
Straight-through tumsBus spec (mm)/  numberInstallation
5P55P105P155P20
P- 170×100II1000/5( 1)102.51/1160×10/ 1-3 80×10/3-6D
1250-2500/5( 1)1551/1
3000/5( 1)2051/1
4000-5000/5( 1)30101/1
P- 180×50II1000-2000/5( 1)15105/1180×10/ 1-3 80×10/3-6
2500-3000/5( 1)20105/1
4000-5000/5( 1)30151/1
P-220×50II1000/5( 1)15102.5/1220×10/ 1-3 100×10/ 1-6
1250-2000/5( 1)15105/1
2500-3000/5( 1)201052.51
4000-6300/5( 1)30151051


Features of AKH-0.66/P Protection Current Transformer

01

AKH-0.66P-I has accurate measurement and strong overload capacity, and can be used in conjunction with ARD2, ARD3 and other motor protection units;

02

The primary current of AKH-0.66/P-M8 is small, and it is mostly used in relay protection circuits, suitable for small space places such as low-voltage drawer cabinets;

03

The AKH-0.66/MP is equipped with two coils, one for measurement and one for protection, which are widely used in electrical complete sets and low-voltage power distribution protection systems.

Diagram of AKH-0.66/P Protection Current Transformer

Diagram of AKH-0.66/P Protection Current Transformer
Dimension
Diagram of AKH-0.66/P Protection Current Transformer
Installation
Diagram of AKH-0.66/P Protection Current Transformer
Wiring
Diagram of AKH-0.66/P Protection Current Transformer
Application
Innovation, Efficiency, Unity, Integrity.
Acrel, your reliable energy meter partner. Don't hesitate to contact us!
Contact Us
Related AKH-0.66 Low Voltage Current Transformer
+8618795636361 michelle.zhou@email.acrel.cn
No. 9 Xincheng Road, Chengjiang Street, Jiangyin City, Jiangsu Province, China.