E-mail

Acrel AKH-0.66/II Horizontal Current Transformer For Busbar

AKH-0.66/II horizontal current transformer for busbar is an instrument that converts a large current on the primary side into a small current on the secondary side based on the principle of electromagnetic induction for measurement. A current transformer consists of a closed core and windings. Its primary side winding has few turns and is connected in series with the current line to be measured.

busbar ct
busbar ct
busbar current transformer
low power instrument transformer
low tension current transformer
Products

Specifications of AKH-0.66/II Horizontal Current Transformer For Busbar

Parameters
SpecificationRated current ratio
(A)
Precision degree and
corresponding rated load
(VA/ Ω)
Straight-through tumsBus spec(mm)/ numberInstallation
0.20.51
30II100/5(1)

1.5130x10/1-2A,C
150/5(1)

1.51
200/5(1)
2.5
1
250/5(1)
3.75
1
300-450/5(1)
5
1
500/5(1)
10
1
600/5
10
1
40II100/5(1)

1.5140×10/1-2A,C
150/5(1)

2.51
200/5(1)
2.5
1
250/5(1)
3.75
1
300-450/5(1)
5
1
500-800/5(1)
10
1
1000/5(1)10

1
50II150

2.5150×10/1-2
200-250/5(1)
2.5
1
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500/5(1)20

1
60II200-250/5(1)
2.5
160×10/1-2C
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500/5(1)30

1
60×50II200-250/5(1)
2.5
160×10/1-3D
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500/5(1)30

1
80II200-250/5(1)
2.5
180×10/1-2
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-3000/5(1)30

1
80×50II200-250/5(1)
2.5
180×10/1-3
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-3000/5(1)30

1
100II300-450/5(1)
5
1100×10/ 1-2
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-4000/5(1)30

1
100×50II300-450/5(1)
5
1100×10/ 1-3
500-800/5(1)
10
1
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-4000/5(1)30

1
100×80II600-800/5(1)
10
1100×10/ 1-4
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-4000/5(1)30

1
120×50II500-800/5(1)
10
1
1000-1250/5(1)10

1120×10/ 1-3
1500-2000/5(1)20

1
2500-5000/5(1)30

1
130×50II600-800/5(1)
10
1125×10/1-3 130×10/1-3 60×10/2-6
1000-1250/5(1)10

1
1500-2000/5(1)20

1
2500-5000/5(1)30

1
120×80II 150×50II1000-1250/5(1)10

1120×10/ 1-4
1500-2000/5(1)20

1
2500-5000/5(1)30

1
170×100II1500-2000/5(1)15

1170×10/1-3 100×10/3-6
2500-5000/5(1)30

1
180×50II1200-2000/5(1)10

1180×10/1-3
2500-5000/5(1)30

1
200×50II 220×50II 260×50II1500-2000/5(1)20

1200×10/1-3 100×10/4-6
2500-5000/5(1)30

1
260×100II1200-1500/5(1)10

1250×10/2-5 125×10/4-10
1500-2000/5( 1)20

1
2500-6300/5( 1)30

1


Features of AKH-0.66/II Horizontal current transformer For Busbar

01

It can pass through 1-6 busbars, and can also pass through multiple cables;


02

It is generally used in conjunction with electrical measuring instruments, and is widely used in electrical complete sets;

03

The clamshell material is made of transparent polycarbonate, which can clearly see the wiring of the secondary lead.

Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR

Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Dimension
Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Specification
Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Specification
Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Specification
Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Installation
Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Wiring
Diagram of AKH-0.66/II HORIZONTAL CURRENT TRANSFORMER FOR BUSBAR
Application
Innovation, Efficiency, Unity, Integrity.
Acrel, your reliable energy meter partner. Don't hesitate to contact us!
Contact Us
Related AKH-0.66 Low Voltage Current Transformer
+8618795636361 michelle.zhou@email.acrel.cn
No. 9 Xincheng Road, Chengjiang Street, Jiangyin City, Jiangsu Province, China.